Kenmore F9MVT0802120A 1051783

Kenmore F9MVT0802120A Gas Furnace, 80000 Btu/hr Input BTU, 115 VAC, 2000 cu-ft/min, 1 hp at 600 - 1200 rev/min, 96% AFUE

  • Manufacturer: Carrier
  • Brand Name: Kenmore
  • Part Number: 1051783
  • MPN: F9MVT0802120A
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

Kenmore Gas Furnace, F9MVT Model, 80000 Btu/hr Input BTU Rating, 115 VAC, 11.7 A Maximum, 15.5 A Unit, 2000 cu-ft/min, 1 hp at 600 - 1200 rev/min, 96% AFUE, 1 -Phase, 60 Hz, Configuration: Multi-Position, 1/2 in NPT Connection, Natural Gas Fuel, 4 -Burner, 10 in W x 11 in Dia Blower Size, 21 in W x 35 in H x 29-1/2 in D Cabinet Dimensions, 5 ton at 400 cu-ft/min, 5.5 ton at 350 cu-ft/min, 40 V-A at 24 VAC Transformer, Steel, 30 - 60 deg F Low, 40 - 70 deg F High Rise

AFUE Rating      :      96 %
Amperage Rating      :      11.7 A Maximum, 15.5 A Unit
Blower Size      :      11 in Dia x 10 in W
CFM Rating      :      2000 cfm
Cabinet Dimensions      :      21 in W x 29-1/2 in D x 35 in H
Configuration      :      Multi-Position
Connection Type      :      1/2 in NPT
Frequency Rating      :      60 Hz
Fuel Type      :      Natural Gas
HP Rating      :      1 hp at 600 to 1200 rpm
Input BTU Rating      :      80000 Btu/hr
Material      :      Steel
Model      :      F9MVT
Number of Burners      :      4
Phase      :      1 ph
Temperature Rise      :      30 - 60 deg F Low, 40 - 70 deg F High
Tonnage      :      5 ton at 400 cfm, 5.5 ton at 350 cfm
Transformer Rating      :      40 VA at 24 VAC
Voltage Rating      :      115 VAC
  • Extra SEER variable speed ECM blower motor
  • Certified to leak 2% or less of nominal air conditioning cu-ft/min delivered when pressurized to 1 in WC with all present air inlets, air outlets and condensate drain ports sealed
  • Tougher - flame roll-out sensors standard, adjustable heating blower off delay, factory set blower on delay, stainless steel RPJ aluminized steel primary heat exchanger, stainless steel secondary heat exchanger, high temperature limit control prevents overheating, direct ignition with silicon nitride igniter
  • Direct vent (2-pipe), single pipe venting or ventilated combustion air
  • 24 VAC humidifier terminal and electronic air cleaner terminal
  • Innovative knobs for easy door removal and secure attachment
  • At least 12 different venting configurations
  • Through the casing flue pipe for counterflow or horizontal applications with accessory
  • Slide out heat exchanger and blower assembly
  • Quieter - operates quieter at lower heating rates, 2-speed induced draft combustion blower, variable speed ECM blower motor
  • Self configuring and communicating control
  • Supports one and two-stage cooling units
  • ECM variable speed blower motor
  • 4.5 - 13.6 in WC inlet gas pressure