WELCOME TO OUR SITE! START SHOPPING!

  1. pin-int

Johnson Controls VFD68CHH-2C 1109662

Johnson Controls VFD68CHH-2C Penn Variable Frequency Drive, 3 hp Motor Output, 460 VAC Input, 3 ph -Phase

  • Manufacturer: Johnson Controls
  • Brand Name: Johnson Controls
  • Part Number: 1109662
  • MPN: VFD68CHH-2C
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

The VFD68 Variable Frequency Drive provides 3-phase motor speed control in a variety of HVAC/R applications. The VFD68 drive is designed primarily for condenser fan speed control on HVAC and refrigeration condensing units, but can also be set up to control a variety of pumps, blowers, and fans. The VFD68 drive accepts an input signal from P499 Electronic Pressure Transducer, or other devices that provide a 0 - 5 VDC, 0 - 10 VDC, or 4 - 20 mA signal. The application-specific design of the VFD68 drive provides a simple interface, which makes the drive easy to understand and operate. You can quickly and easily reconfigure the VFD68 drive to control variable speed pumps in cooling and heating applications, or to control variable speed supply fans in VAV applications. The VFD68 drive is an RS485, RTU-compliant ModBus slave device and can be integrated into a ModBus network.

Johnson Controls Penn Variable Frequency Drive, 3 hp Motor Output, 60 Hz Output, 460 VAC Input, 3 ph, NEMA 1, 5 in H x 4-1/4 in W x 6-1/8 in D, Additional Information: 2.2 kW Power Rating, -40 to 122 deg F Temperature Rating

Additional Information      :      2.2 kW Power Rating, -40 to 122 deg F Temperature Rating
Dimensions      :      5 in H x 4-1/4 in W x 6-1/8 in D
Enclosure Type      :      NEMA 1
Input Voltage      :      460 VAC
Motor Output      :      3 hp
Output Frequency      :      60 Hz
Phase      :      3 ph
  • Selectable input types allows use with 0 to 5 VDC (ratiometric), 0 - 10 VDC, or 4 - 20 mA input signals from transducers, sensors, and controllers
  • High input signal selection of two similar inputs (230 or 460 V models only) provides fan speed control of dual circuit condensing units, based on the highest pressure circuit
  • Compact design provides for easy and flexible installation
  • 3 phase, 230, 460, or 575 VAC models can control a wide variety of 3 phase motors ranging upto 10 hp
  • Simple and advanced end-user settings provide quick and simple application setup and operation, as well as advanced setup parameters for custom applications
  • Adjustable 0.7 - 15 kHz PWM carrier frequency
  • Three PH NEMA design B motors required, inverter-rated motors recommended
  • 150% of ampere rating for 1 min overload capacity
  • Use STF input to start or stop the motor
  • UL type 1 (NEMA) fan cooled enclosures
  • Up to 100 m (328 ft) between the VFD68 drive and the motor maximum high voltage wire length
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Johnson_Controls_VFD68CHH_2C_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Johnson_Controls_VFD68CHH_2C_Manual.pdf