Honeywell AQ25242B/U 1017614

Honeywell Aquatrol AQ25242B/U Mixing Boiler Reset Control Panel with DHW Priority, NTC Thermistor Sensor, 4 -Zone

  • Manufacturer: Honeywell International Inc
  • Brand Name: Honeywell
  • Part Number: 1017614
  • MPN: AQ25242B/U
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

Honeywell Aquatrol Mixing Boiler Reset Control Panel with DHW Priority, 120 VAC at 60 Hz Power Supply, NTC Thermistor Sensor, User Interface: LCD Display and 7 Button Key Pad, 4 -Zone, 120 - 225 deg F Maximum, 59 - 180 deg F Minimum Supply and 2 - 41 deg F Differential (Boiler) and -60 to 32 deg F (Outdoor Low Design) Control, 24 VAC, 0.5 A, 12 V-A Boiler Output, 120 - 250 VAC, 5 A, 1/3 hp Pump, 24 VAC, 0.5 A, 12 V-A Valves Contact, 10 ft L Lead, 2 x 14 AWG Wire, Wire Clamp Screw Terminal Connection, 5 - 90% RH Non-Condensing Humidity, 7 days, Up to 2 Setback Periods/day Program Programmability, 32 - 130 deg F Panel, -58 to 230 deg F Sensor, 16-1/2 in W x 8 in H x 3-3/8 in D

Boiler Output      :      24 VAC, 0.5 A, 12 V-A
Connection Type      :      Wire Clamp Screw Terminal
Contact Rating      :      120 - 250 VAC, 5 A, 1/3 hp Pump, 24 VAC, 0.5 A, 12 V-A Valves
Control Range      :      120 - 225 deg F Maximum, 59 - 180 deg F Minimum Supply and 2 - 41 deg F Differential (Boiler) and -60 to 32 deg F (Outdoor Low Design)
Dimensions      :      16-1/2 in W x 8 in H x 3-3/8 in D
Humidity Rating      :      5 - 90% RH Non-Condensing
Lead Length      :      10 ft
Number of Zones      :      4
Power Supply      :      120 VAC at 60 Hz
Programmability      :      7 days, Up to 2 Setback Periods/day Program
Sensor Type      :      NTC Thermistor
Temperature Rating      :      32 - 130 deg F Panel, -58 to 230 deg F Sensor
User Interface      :      LCD Display and 7 Button Key Pad
Wire Size      :      2 x 14 AWG
  • Controls (1) boiler and (1) mixing (either variable speed injection or floating valve mixing) loop in a hydronic zoning system
  • Customizable control settings allow for greater control and comfort
  • Intuitive and accessible programming interface and central program of zone set points and setback
  • Automated test and purge feature for quick start-up and troubleshooting
  • Line and low-voltage output and domestic hot water priority and priority override protection
  • Non-volatile EPROM memory retains program settings
  • Zoning devices controlled - zone pumps or two-wire valves
  • Boiler short cycling protection, boiler post purge and boiler shock prevent from cold water returning to boiler
  • 10 sec to 30 min off boiler heat post-purge
  • 30 sec per 2 weeks of space heating inactivity pump/valve exercise
  • Heat demand (thermostat R-W), auxiliary demand and DHW demand, external dry contacts connection only
  • Low voltage, Class II, two-wire polarity-insensitive, digital communicating link to other control or zoning modules
  • Auxiliary low voltage - 24 VAC, 0.5 A, 12 V-A, boiler pump - 120/250 VAC, 5 A, 1/3 hp, DHW pump/valve - 120 VAC, 5 A, 1/3 hp, auxiliary pump - dry contact output, 120/250 VAC, 5 A, 1/3 hp
  • Mixing valve floating output - 24 VAC rated dry contacts
  • Mixing valve modulating output - 0 - 10 VDC
  • Secondary pump output rating - 120 VAC, 5 A, 1/3 hp and variable speed injection pump output - triac modulated, 120 VAC, 2.1 A, 1/6 hp
  • Warm weather shut down temperature - 35 - 100 deg F