Honeywell AQ25142B 1007652

Honeywell AQ25142B Boiler Reset Control, NTC Thermistor Sensor, User Interface: LCD Display and 7 Button Key Pad

  • Manufacturer: Honeywell International Inc
  • Brand Name: Honeywell
  • Part Number: 1007652
  • MPN: AQ25142B
  • UPC: 085267926317
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

Honeywell Boiler Reset Control, 120 V, 50/60 Hz, NTC Thermistor Sensor, LCD Display and 7 Button Key Pad User Interface, 4-Zones, 120 to 255 deg F Boiler, -60 to 32 deg F Outdoor Low Design Control Range, 24 V, 0.5 A, 12 VA Boiler Output, 5A at 120- 250 VAC Pumps, 0.5 at 24 VAC Valves Contact Rating, 10 ft Lead Length, (2) 14 AWG Wire, Wire Clamp Screw Connection, -32 F to 130 deg F Panel, -58 F to 230 deg F Sensor, 8 in H x 16-1/2 in W x 3-3/8 in D

Boiler Output      :      24 V, 0.5 A, 12 VA
Connection Type      :      Wire Clamp Screw
Contact Rating      :      5A at 120 - 250 VAC Pumps, 0.5 at 24 VAC Valves
Control Range      :      120 to 255 deg F Boiler, -60 to 32 deg F Outdoor Low Design
Dimensions      :      8 in H x 16-1/2 in W x 3-3/8 in D
Frequency Rating      :      50/60 Hz
Lead Length      :      10 ft
Number of Zones      :      4
Sensor Type      :      NTC Thermistor
Temperature Rating      :      -32 F to 130 deg F Panel, -58 F to 230 deg F Sensor
User Interface      :      LCD Display and 7 Button Key Pad
Voltage Rating      :      120 V
Wire Size      :      (2) 14 AWG
  • Displays outdoor temperature on all AQ1000 thermostats when used with the included AQ12C10 outdoor sensor
  • Customizable control settings allow for greater control and comfort, domestic hot water priority and priority override protection, as well as an automated test and purge feature
  • Intuitive and accessible programming interface and central program of zone setpoints and setback programming
  • Zoning control for up to four zones and can be up to 64 zones using expansion panels, test and purge feature for quick start up and simplified troubleshooting
  • Boiler short cycling protection, boiler post purge and boiler shock prevent from cold water returning to boiler
  • 10 sec to 30 min off boiler heat post purge
  • 30 sec per two-weeks of space heating inactivity pump or valve exercise
  • Heat demand (thermostat R-W), auxiliary demand and DHW demand, external dry contacts connection only
  • Low voltage, class II, two-wire polarity-insensitive, digital communicating link to other control or zoning modules
  • 0 to 10 VDC modulating output for driving a modulating/condensing boiler
  • pdfCatalog https://assets.unilogcorp.com/267/ITEM/DOC/Honeywell_AQ25142B_Catalog.pdf
  • pdfInstruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Honeywell_AQ25142B_Instruction_Installation_Manual.pdf
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Honeywell_AQ25142B_Specification_Sheet.pdf