Rheem® Air Handler, Series: RHSL, 3.5 ton Nominal, 42000 Btu/hr BTU, 115 VAC, 12.31 kW, 1/2 hp, 60 Hz, 1 -Phase, 1400 - 1600 cu-ft/min, Configuration: Multi-Position, 13 SEER, 3/8 in Sweat Liquid, 7/8 in Sweat Vapor Connection, R-410A Refrigerant, Steel, Pre-Painted, 21 in W x 50-1/2 in H x 21-11/16 in D
Amperage Rating |
: |
44.4 A Minimum Circuit |
BTU Rating |
: |
36000 Btu/hr Cooling, 27.3 KBtu/hr Heating |
CFM Rating |
: |
1040 - 850 cu-ft/min Low, 1050 - 74 cu-ft/min High |
Configuration |
: |
Horizontal |
Connection Type |
: |
3/8 in Liquid, 3/4 in Suction |
Dimensions |
: |
49-1/4 in L |
Filter Size |
: |
20 x 20 x 1 in |
Finish |
: |
Galvanized, Powder-Coated |
Frequency Rating |
: |
60 Hz |
Fuse Rating |
: |
45 A |
HP Rating |
: |
1/3 hp |
Material |
: |
Steel |
Mounting Type |
: |
Ceiling |
Nominal Capacity |
: |
3 ton |
Phase |
: |
1 PH |
Refrigerant Type |
: |
R-22, R-410A |
SEER Rating |
: |
13 |
Series |
: |
RHSL |
Voltage Rating |
: |
240 V |
Wattage |
: |
8 kW |
- Attractive pre-painted cabinet exterior, rugged wall steel cabinet construction, designed for added strength and versatility
- 1 in foil faced insulation mechanically retained in blower compartment
- Four leg rubber insulated wire motor mount
- Blower housing with integrated controls, motor and blower, slide-out design for service and maintenance convenience
- Field convertible for vertical upflow, vertical down flow, horizontal left hand or right hand air supply
- Three combustible floor base accessories fit all model sizes when required for down flow installations on combustible floors
- Indoor coil design provides low air side pressure drop, high-performance and extremely compact size
- Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil
- Coils are constructed of aluminum fins bonded to internally grooved copper tubing
- Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils
- Supply duct flanges provided as standard on air handler cabinet
- Front refrigerant and drain connections
- 19-3/8 in W x 19-3/4 in D return air opening
- 19-1/2 in supply duct
- 3/4 in auxiliary, primary drain connection
- PSC, two speed blower motor
- 10 x 10 in blower
- 49 deg F maximum electric heat rise
- 1st design variation
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS36G_000_HTS08_Catalog.pdf
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Rheem_RHSL_HM3621JA_Catalog.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS36G_000_HTS08_Installation_Sheet.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Rheem_RHSL_HM3017JA_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS36G_000_HTS08_Specification_Sheet.pdf