Rheem® Air Handler with TEV Metering, Series: RF1T, 3 ton Nominal, 36000 Btu/hr Cooling BTU, 208/240 VAC, 17.3/20 A Circuit, 25/29 A Minimum Circuit, 2.5 A Motor, 10.6 kW Cooling, 5 kW Heating, 1/2 hp, 60 Hz, 1 -Phase, 1000 - 1200 cu-ft/min, 14.5 SEER, R-410A Refrigerant, 25/30 A Fuse, 20 x 25 x 1 in Filter, 1 -Stage, Steel, 24 in W x 36 in H x 21 in D
Amperage Rating |
: |
52.7 A Minimum Circuit |
BTU Rating |
: |
30000 Btu/hr Cooling, 32.8 KBtu/hr Heating |
CFM Rating |
: |
965 - 650 cu-ft/min Low, 1085 - 74 cu-ft/min High |
Configuration |
: |
Horizontal |
Connection Type |
: |
3/8 in Liquid, 3/4 in Suction |
Dimensions |
: |
43-1/4 in L |
Filter Size |
: |
20 x 20 x 1 in |
Finish |
: |
Galvanized, Powder-Coated |
Frequency Rating |
: |
60 Hz |
Fuse Rating |
: |
60 A |
HP Rating |
: |
1/3 hp |
Material |
: |
Steel |
Mounting Type |
: |
Ceiling |
Nominal Capacity |
: |
2.5 ton |
Number of Stages |
: |
1 |
Phase |
: |
1 PH |
Refrigerant Type |
: |
R-22, R-410A |
SEER Rating |
: |
14.5 |
Series |
: |
RF1T |
Voltage Rating |
: |
240 V |
Wattage |
: |
10 kW |
- Rugged wall steel cabinet construction, designed for added strength and versatility
- 1 in foil faced insulation for excellent thermal and sound performance
- Four leg blower motor mount
- Traditional open wire element design for heat applications
- Indoor coil design provides low air side pressure drop, high-performance and extremely compact size
- Coils are constructed of aluminum fins and internally grooved aluminum tubing
- Molded polymer corrosion resistant condensate drain pan is provided for all indoor coils
- Connection point for high voltage wiring is inside the air handler cabinet, low voltage connection is made on the outside of the air handler cabinet
- Concentric knockouts are provided for power connection to cabinet, Installer may pull desired hole size upto 1-3/8 in for 7/8 in conduit
- Constant torque, two speed X-13(ECM) motor
- Minor - major Series
- 23 in W x 21-3/8 in H return air opening
- 10 x 8 in blower
- 44 deg F maximum electric heat rise
- Breaker disconnect configuration
- One supply circuit
- Factory installed condensate float switch which shuts off the outdoor unit in event the condensate pan becomes clogged
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS30G_000_HTS10_Catalog.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS30G_000_HTS10_Installation_Sheet.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Rheem_RF1T3624MTANJAB03_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Aspen_GAS30G_000_HTS10_Specification_Sheet.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Rheem_RF1T3624MTANJAN00_Specification_Sheet.pdf