Raypak® RayTherm Hydronic Gas Boiler, 120 VAC, >5 A, 82.7 % AFUE, 264 MBtu/hr Input, 216 MBtu/hr Output, 12 psi Minimum, 160 psi Maximum, 3/4 in Gas, 1-1/2 in Water, 7 in Vent Connection, Natural Gas, Propane Gas Fuel, Motorized Vent Damper Vent, Steel, Powder-Coated, Polytuf, 22-3/8 in W x 26-1/2 in D x 62-7/8 in H
AFUE Rating
:
82.7 %
Amperage Rating
:
>5 A
BTU Rating
:
264 MBtu/hr Input, 216 MBtu/hr Output
Color
:
Polytuf
Connection Type
:
3/4 in Gas, 1-1/2 in Water, 7 in Vent
Dimensions
:
22-3/8 in W x 26-1/2 in D x 62-7/8 in H
Finish
:
Powder-Coated
Fuel Type
:
Natural Gas, Propane Gas
Material
:
Steel
Pressure Rating
:
12 psi Minimum, 160 psi Maximum
Vent Type
:
Motorized Vent Damper
Voltage Rating
:
120 VAC
Rugged all-brass headers resist corrosion, and are easily removed for inspection or service, AB 1953 compliant, glass-lined cast-iron headers and cupro-nickel tubes are available as options
Finned copper tube heat exchanger single bank, straight through design delivers lowest pressure drop, Integral fins have ten times the heat transfer surface of plain tubes, 82% efficiency, Cat I venting, indoor/outdoor certified
Corrosion-resistant steel fittings are brush galvanized against rust, heat shields are corrosion-resistant steel, jacket has polytuf powder-coat finish
24 V controls are totally enclosed for protection, door is easily removed for inspection and service
Floating return header immunizes heat exchanger to thermal shock
Tube sheet and O-ring construction eliminates the repair and maintenance problems associated with rolling tubes directly into a casting, electronic controller with outdoor reset varies the setpoint as the air temperature changes
Interlocking refractory panels with sealed corners reduce radiation losses
Stainless steel burners maintain precise combustion at all firing rates, burn quietly and won't clog or corrode
Slide-out burner tray allows easy inspection and service
Non-condensing operates at 105 deg F return water temperature without condensing, perfect for the low-temperature needs of radiant floor and snow melting systems
Spark-to-hood pilot eliminates erratic pilot ignition and lockout
Motorized vent damper prevents heat loss during off-cycles
Non-ferrous waterways brass fittings and glass-lined headers eliminate boiler oxygen-permeation problems associated with non-barrier radiant tubing
Radiant heating
Hydronic space heating
Snow melting
Light commercial
Standard outdoor reset control
Indirect fired water heating (with indirect storage tank)