WELCOME TO OUR SITE! START SHOPPING!

  1. pin-int

Raypak® H3-0260 1117539

Raypak® H3-0260 RayTherm Hydronic Gas Boiler, 82.7 % AFUE, 264 MBtu/hr Input, 216 MBtu/hr Output BTU, 120 VAC, Steel

  • Manufacturer: Rheem Manufacturing
  • Brand Name: Raypak®
  • Part Number: 1117539
  • MPN: H3-0260
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • Sign In for Availability

Raypak® RayTherm Hydronic Gas Boiler, 120 VAC, >5 A, 82.7 % AFUE, 264 MBtu/hr Input, 216 MBtu/hr Output, 12 psi Minimum, 160 psi Maximum, 3/4 in Gas, 1-1/2 in Water, 7 in Vent Connection, Natural Gas, Propane Gas Fuel, Motorized Vent Damper Vent, Steel, Powder-Coated, Polytuf, 22-3/8 in W x 26-1/2 in D x 62-7/8 in H

AFUE Rating      :      82.7 %
Amperage Rating      :      >5 A
BTU Rating      :      264 MBtu/hr Input, 216 MBtu/hr Output
Color      :      Polytuf
Connection Type      :      3/4 in Gas, 1-1/2 in Water, 7 in Vent
Dimensions      :      22-3/8 in W x 26-1/2 in D x 62-7/8 in H
Finish      :      Powder-Coated
Fuel Type      :      Natural Gas, Propane Gas
Material      :      Steel
Pressure Rating      :      12 psi Minimum, 160 psi Maximum
Vent Type      :      Motorized Vent Damper
Voltage Rating      :      120 VAC
  • Rugged all-brass headers resist corrosion, and are easily removed for inspection or service, AB 1953 compliant, glass-lined cast-iron headers and cupro-nickel tubes are available as options
  • Finned copper tube heat exchanger single bank, straight through design delivers lowest pressure drop, Integral fins have ten times the heat transfer surface of plain tubes, 82% efficiency, Cat I venting, indoor/outdoor certified
  • Corrosion-resistant steel fittings are brush galvanized against rust, heat shields are corrosion-resistant steel, jacket has polytuf powder-coat finish
  • 24 V controls are totally enclosed for protection, door is easily removed for inspection and service
  • Floating return header immunizes heat exchanger to thermal shock
  • Tube sheet and O-ring construction eliminates the repair and maintenance problems associated with rolling tubes directly into a casting, electronic controller with outdoor reset varies the setpoint as the air temperature changes
  • Interlocking refractory panels with sealed corners reduce radiation losses
  • Stainless steel burners maintain precise combustion at all firing rates, burn quietly and won't clog or corrode
  • Slide-out burner tray allows easy inspection and service
  • Non-condensing operates at 105 deg F return water temperature without condensing, perfect for the low-temperature needs of radiant floor and snow melting systems
  • Spark-to-hood pilot eliminates erratic pilot ignition and lockout
  • Motorized vent damper prevents heat loss during off-cycles
  • Non-ferrous waterways brass fittings and glass-lined headers eliminate boiler oxygen-permeation problems associated with non-barrier radiant tubing
  • Radiant heating
  • Hydronic space heating
  • Snow melting
  • Light commercial
  • Standard outdoor reset control
  • Indirect fired water heating (with indirect storage tank)
  • 2-stage firing mode
  • pdfSpecification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Raypak_H3_0260_Specification_Sheet.pdf