RUUD® Commercial Air Handler, Series: RHGN-H120, 10 ton Nominal, 285000 Btu/hr Steam, 240000 Btu/hr Water BTU, 460 VAC, 35 kW, 2 hp, 60 Hz, 3 -Phase, 4000 cu-ft/min, Configuration: Horizontal/Vertical, R-410A Refrigerant, 15 A Fuse, (4) 16 x 25 x 1 in Filter, 2 -Stage, Steel, Galvanized, Pre-Painted
BTU Rating |
: |
285000 Btu/hr Steam, 240000 Btu/hr Water |
CFM Rating |
: |
4000 cfm |
Configuration |
: |
Horizontal/Vertical |
Filter Size |
: |
(4) 16 x 25 x 1 in |
Finish |
: |
Galvanized/Pre-Painted |
Frequency Rating |
: |
60 Hz |
Fuse Rating |
: |
15 A |
HP Rating |
: |
2 hp |
Material |
: |
Steel |
Nominal Capacity |
: |
10 ton |
Number of Stages |
: |
2 |
Phase |
: |
3 ph |
Refrigerant Type |
: |
R-410A |
Series |
: |
RHGN-H120 |
Voltage Rating |
: |
460 VAC |
Wattage |
: |
35 kW |
- Cabinet - unit cabinet should be constructed of galvanized, pre-painted steel
- Motor - inherently protected motors are mounted inside of insulated cabinet to reduce motor noise
- A choice of motor horsepower's and drive combinations are available to allow you to meet specified cu-ft/min at various static pressures upto 2 in external static pressure
- Low profile - allows for horizontal installation in most standard drop ceiling applications, and the movement of units through most standard doorways for addition or replacement work
- Thermal expansion valves - standard all models
- Filters - 1 in throwaway filters are standard, but filter racks are designed to accept either 1 or 2 in filters
- Evaporator coil - two-circuit, interlaced row split coils are constructed with copper tubes and aluminum fins mechanically bonded to the tubes for maximum heat transfer capabilities, all coil assemblies are leak tested up to 450 lbf/sq-in internal pressure prior to installation into units
- Refrigerant connections - field piping connections are made through a fixed post between two side access panels on either side of the unit
- Allows flexibility to meet most field conditions as well as full accessibility after the installation is complete
- Units may be used with two straight cool condensing units or single circuit manifold in the field using the copper fittings shipped with each unit
- The RHGN air handler has not been tested, rated or certified to operate with dual residential remote heat pumps
- Drain pan - the galvanized steel drain pan is designed to trap condensate in either vertical or horizontal installations, condensate drain connections are located on both sides of the unit allowing complete flexibility to meet most field conditions
- Service access - 2-removable panels on top and each side of the unit are easily removed for access to motors, blowers, sheaves, and filters
- Horizontal or vertical - all models are designed for either application and can be installed in either position as supplied from the factory
- Testing - all units are run tested at the factory prior to shipment, units are shipped with a holding charge of nitrogen
- Variable frequency drive - provides two-stage airflow for improved part load efficiency and dehumidification, meets California Title 24 requirements
- S-drive package